Indoor Air Quality Testing for BREEAM

Indoor Air Quality Testing for BREEAM

Depending on the building certification standard you are wanting to achieve i.e., BREEAM, LEED and/or WELL certification, you may need to carry out an initial detailed assessment of air quality followed by ongoing long-term monitoring. Typical indoor air quality pollutants that require monitor range from volatile organic compounds (VOC’s) Formaldehyde to key gas indicators such …

Read More Read More

Improving your Air Testing

Improving your Air Testing

Improving your Air Testing with Good Construction Detailing Air Testing is the simplest and most popular method used in the construction industry to confirm compliance with Part L of the Building Regulations. The air test is simply a test of the building fabric integrity. Draughts and heat loss often occur wherever there is a hole …

Read More Read More

What can APT Sound Testing do for you?

What can APT Sound Testing do for you?

At APT Sound Testing, we offer Airborne and Impact Sound Insulation Testing in accordance with Part E of the Building Regulations and, where required sound testing on Schools BB93 & BREEAM. Under Part E of Building Regulations, this is a requirement for new and converted dwellings where there is a separating partition wall or floor. …

Read More Read More

How Many Air Tightness Tests do I need?

How Many Air Tightness Tests do I need?

How Many Air Tightness Tests do I need? The air tightness test can be carried out on a selection of dwellings/ building types – three units of each type or 50% of that type, whichever is fewer. It many cases it is necessary to test all plots, otherwise a 2m3/hr/m2 penalty must be applied to …

Read More Read More

How to Pass an Air Tightness Test for Building Control Signoff

How to Pass an Air Tightness Test for Building Control Signoff

With the tightening of Building Regulations Part L later this year, it is now mandatory that air tightness testing is carried out to all new flats, houses and commercial buildings. Previously, it was possible to undertake testing to a just a sample of the units; however, this wasn’t deemed accurate and so the new regulations …

Read More Read More

Air Tightness Testing on all New Dwellings

Air Tightness Testing on all New Dwellings

Is Air Tightness Testing Mandatory on all New Dwellings? Yes! From June 2022 all new builds need to demonstrate a minimum level of air permeability of 8m³/h.m²; however, this figure is often lower to align with the design stage SAP assessment. There won’t be an option to undertake ‘sample testing’ with the new Building Regulations …

Read More Read More

Thermal Imaging Surveys

Thermal Imaging Surveys

APT Sound Testing provide UKAS accredited sound testing & Thermal Imaging Surveys for London and the whole of the UK as required by Approved Document E of the Building Regulations. We undertake projects on all types of residential buildings and commercial buildings. We also undertake sound testing on schools and buildings containing rooms for residential …

Read More Read More

Improving Acoustics in Dwellings

Improving Acoustics in Dwellings

When designing a new project containing multiple dwellings, why go further than just meeting the basic regulations. For instance, if you only manage to achieve the minimum requirements for compliance with Building Regulations Part E for sound testing, then the chance of noise complaints will usually be higher than if you better it by 5-7dB.   …

Read More Read More

Improving your Air Test with Good Construction

Improving your Air Test with Good Construction

Improving your Air Test with Good Construction Detailing Since April 2006, air testing has been required to be tested for Air Permeability, in order to comply with Part L1 & L2 of the Building Regulations.  Since 2011 the air leakage target has reduced from 10m3/hr/m2 to 5m3/hr/m2. In the next 2 years it is expected …

Read More Read More

Air Tightness Testing & Smoke Surveys

Air Tightness Testing & Smoke Surveys

Air Tightness Testing & Smoke Surveys to Fix Leaky Buildings This article explains the use of combined air tightness testing and smoke surveys to evaluate and fix air leakage paths in houses and commercial buildings. On past projects where we have encountered very ‘leaky’ buildings, we have managed to lower air leakage rates from 40m3/hr/m2, …

Read More Read More